Product Details:
|
| Rib Profile: | Flat Rib, 3 Mm Rib Height | Rib Pitch: | 100 Mm |
|---|---|---|---|
| Base Metal Thickness: | 0.40 Mm | Sheet Width: | 600 Mm |
| Sheet Length: | 2400 Mm | Zinc Coating: | Z275 Galfan / Hot Dipped Galvanized |
| Nominal Plaster Thickness: | 8 - 20 Mm | ||
| Highlight: | flat rib lath sheet,flat rib plaster carrier,machine sprayed lath ceiling |
||
Flat rib lath and V rib lath are not interchangeable, and specifying the wrong one is why a ceiling ends up wavy. A flat rib profile gives the plaster a wide, level bearing line at each rib instead of a sharp valley, so the coat thickness stays constant across the sheet and the finished face reads flat under raking light. This sheet is made for ceilings and wall linings where a straight edge, a level tolerance or a machine applied coat matters: 0.4 mm base metal, 600 mm width, 2400 mm length, flat rib at 100 mm pitch, galvanized for internal and sheltered external work.
Key Features| Parameter | Specification |
|---|---|
| Rib profile | Flat rib, 3 mm rib height |
| Rib pitch | 100 mm |
| Base metal thickness | 0.40 mm (0.30 to 0.50 mm available) |
| Sheet width | 600 mm (450 mm and 700 mm available) |
| Sheet length | 2400 mm (1800 to 3000 mm available) |
| Zinc coating | Z275 galfan or hot dipped galvanized |
| Opening pattern | Expanded diamond mesh with flat rib stiffeners |
| Nominal plaster thickness | 8 mm to 20 mm |
| Bundle | 10 sheets per bundle, edge protected |
| Consideration | Flat Rib Lath | V Rib Lath |
|---|---|---|
| Finished face flatness | Level bearing, minimal rib shadow | Rib shadow appears in thin coats |
| Plaster thickness range | 8 mm to 20 mm | 12 mm to 30 mm and above |
| Best application | Ceilings, linings, machine applied work | Thick beds, uneven substrates, external render |
| Stiffness across span | Good at close support spacing | Higher, tolerates wider support spacing |
| Rework risk on level sensitive work | Low | Higher |
Commercial ceilings with strict line and level requirements use flat rib lath over furring channels, because the finished plane can be checked with a laser and corrected before the finish coat. Wall linings in corridors, stairwells and plant rooms use the same sheet where blockwork is out of tolerance and a dry lining would need a separate frame. Machine applied plaster contractors favour flat rib for large ceiling runs, since the spray coat sits evenly and the rule does not catch in the ribs. Refurbishment of older buildings uses it to re-line a ceiling that has lost its original key, keeping the existing profile and avoiding the weight of a board and skim build. Sheltered soffits and canopies use the galvanized version where a breathable, non combustible carrier is wanted.
Installation PracticeFix to furring channels or timber battens at 400 mm to 450 mm centers, with the flat rib running across the supports. Lap sheets by one rib and tie at 300 mm intervals with 1.2 mm soft annealed wire. Where a level is critical, set a laser line, pack the channels to that line, then fix the lath, so that the final face depends on the channels rather than on the substrate. Apply the scratch coat so mortar keys through the openings without filling the ribs, allow it to cure, then bring the finish coat to the required tolerance. Keep a 10 mm to 15 mm clearance around service penetrations and back fix any unsupported margins.
Packaging & Quality AssuranceSheets are bundled ten to a pack, edge protected and strapped, with mill certificates stating base metal thickness and zinc coating weight. Each batch is checked for rib height, pitch, sheet dimension and opening pattern before loading. Provide the support spacing, the coat thickness and the tolerance class for the ceiling, and we will confirm sheet thickness, rib height and the fixing layout that suits the specification.
Contact Person: Mr. Harrison
Tel: +8616631807785