Product Details:
|
| Material: | Hot-dip Galvanized Steel | Sheet Width: | 700mm |
|---|---|---|---|
| Sheet Length: | 2500mm | Rib Depth: | 6-20mm |
| Rib Distance: | 100-150mm | Sheet Thickness: | 0.40-0.55mm |
| Coverage: | 1.75 M2 Per Panel | Bundle: | 50 Panels |
| Highlight: | wide sheet rib lath,700mm wide plaster lath,long run ceiling lath |
||
Wide sheet rib lath is the same ribbed plaster base in a 700mm by 2500mm format, sized for the large flat areas that dominate shopping centres, warehouses, car parks and transport interchanges. Every lap in a ceiling is a potential crack line and a slow operation at height, so reducing the panel count per square meter from roughly 1.9 to 0.6 cuts both the lap length and the time a crew spends on a tower or a scissor lift.
The panel keeps its rib stiffness over the wider format because the sheet is roll-formed at 0.40-0.55mm and the ribs are held at 100-150mm pitch across the full 700mm width. Handling is the trade-off, and the format is normally specified where a two-man lift is available and where the ceiling grid has already been set out to a 600mm or 700mm module so that fixing lines and panel edges line up without cutting.
Key Features| Parameter | Specification |
|---|---|
| Material | Hot-dip galvanized steel sheet |
| Surface Treatment | Galvanized, zinc 120-275 g/m2 |
| Rib Depth | 6-20mm |
| Rib Distance | 100-150mm |
| Sheet Width | 700mm |
| Sheet Length | 2500mm |
| Sheet Thickness | 0.40-0.55mm |
| Panel Coverage | 1.75 square meters per panel |
| Open Area | 35-60 percent |
| Bundle Size | 50 panels per bundle |
The format suits high level ceilings in retail, logistics and transport buildings, long soffits under canopies and loading docks, and wall areas where the scaffold is set for a full panel reach. It is also used on mezzanine undersides and plant rooms where services are dense and the plasterer needs to work quickly between hangers.
Because the panels cover a wide area, they are also chosen for staged handover, where a ceiling zone must be closed and painted to allow the next trade in while the rest of the floor is still open.
Installation and HandlingPanels are lifted in bundles to the working level, then positioned with the ribs running across the ceiling members and the long edge parallel to the main runner. Fixing is at 150mm centres on all edges and at every second rib across the width, using galvanized screws with washers or tie wire to the runner clips.
Two installers work as a pair: one holds the panel on the lift platform while the other fixes the leading edge, then both work back along the panel. Panels are never folded or walked on; a damaged panel is cut down and used for infill rather than straightened on site.
Packaging and Quality AssuranceFifty panels form a bundle of roughly 87 square meters, strapped to a timber pallet with lifting slings threaded for crane handling and a waterproof cover over the top face. The bundle footprint matches a standard truck bed so it can be transferred straight from container to site vehicle.
Checks cover panel width tolerance, rib height, diagonal squareness and thickness, because a wide panel that is out of square shows immediately on a grid ceiling. Each bundle label states the lot number, coverage area and the rib specification for site reconciliation.
Contact Person: Mr. Harrison
Tel: +8616631807785