|
Product Details:
|
| Material: | Galvanized Steel DX51D | Rib Depth: | 4-8mm |
|---|---|---|---|
| Rib Distance: | 75mm | Sheet Width: | 200-600mm |
| Sheet Length: | 1500-2000mm | Sheet Thickness: | 0.25-0.40mm |
| Zinc Coating: | 60-120 G/m2 | Plaster Build: | 6-12mm |
| Highlight: | fine rib lath,thin coat ceiling lath,lightweight plaster carrier |
||
Fine rib lath answers a specific problem on suspended ceilings: the plaster needs a continuous mechanical key, but the structure has no allowance for a deep rib profile or a heavy sheet. The panel is roll-formed from 0.25-0.40mm galvanized sheet into a shallow 4-8mm V-rib at 75mm centres, so a 6mm plaster coat already covers the rib crown and the whole assembly stays inside the deflection budget of the ceiling grid.
Shallow ribs also mean less shadowing. Where deep rib lath can telegraph its profile through a thin finish, the fine rib pattern sits close to the plane of the sheet and disappears under a skim coat, which is why it is chosen for hospital corridors, office soffits and apartment ceilings where a flat painted finish is the acceptance criterion. Weight is held near 1.6-2.2 kilograms per square meter, roughly a third less than a heavy ribbed panel of the same area.
Key Features| Parameter | Specification |
|---|---|
| Material | Galvanized steel sheet, DX51D |
| Surface Treatment | Hot-dip galvanized, zinc 60-120 g/m2 |
| Rib Depth | 4-8mm |
| Rib Distance | 75mm |
| Sheet Width | 200-600mm |
| Sheet Length | 1500-2000mm |
| Sheet Thickness | 0.25-0.40mm |
| Weight | 1.6-2.2 kg per square meter |
| Open Area | 40-65 percent |
| Recommended Plaster Build | 6-12mm total |
The panel is used for plasterboard-free ceiling construction in apartments, offices, schools and clinics, and for over-cladding existing damaged ceilings where the old plaster is stripped back to the joists. It also works well on curved soffits and bulkheads, because the fine rib bends to a tighter radius than a heavy lath without kinking.
In refurbishment the shallow profile lets a contractor add a new plaster base beneath an existing concrete slab without losing headroom, which matters in basement car parks, service corridors and stair cores where every 10mm of build-up counts.
Installation and HandlingSheets are laid with the ribs running perpendicular to the ceiling joists and fixed at 150mm centres with galvanized screws or staples, using a washer head so the light gauge is not pulled through. Laps of 25mm are made on the long edges and tied at 200mm intervals before the first coat is applied.
Because the sheet is thin, panels are carried on edge rather than dragged, and site stacking is limited to 40 sheets to avoid crushing the ribs at the bottom of the pile. A bonding agent is applied over the lath before the scratch coat on very smooth concrete soffits.
Packaging and Quality AssuranceBundles hold 200 sheets with kraft paper between every twentieth sheet, corner protectors on all four edges and two PET straps per bundle. Pallets are covered with a shrink hood for container shipment, and a moisture indicator is placed inside each hood for long sea routes.
Inspection covers rib depth, rib pitch, zinc coating weight, sheet thickness and flatness. A sample sheet from each lot is plastered in the workshop to confirm that the coat keys through the apertures and that no rib telegraphs through a 6mm finished thickness.
Contact Person: Mr. Harrison
Tel: +8616631807785